ak 1100 OXYGEN SCAVENGER
GENERAL DESCRIPTION
ak 1100 is a catalyzed oxygen scavenger in liquid form.
PRINCIPAL USES
ak 1100 is an oxygen scavenger designed to control oxygen corrosion in boiler systems with/or without deaerators. ak 1100 should always be applied together with an internal scale/deposit inhibitor for a complete boiler treatment program.
PRODUCT BENEFITS
- Reduces dissolved oxygen in boiler feed water systems to protect from corrosion
- Catalyzed form for faster reaction at lower temperatures
- Enhanced formula prevents activity loss during long term storage and usage
- Complies with FDA and USDA regulations in food industry, potable water, sterilization and steam humidification
- Can be used at pressures up to 40 bars
DOSAGE
The specific dosage of ak 1100 varies depending on the amount of dissolved oxygen present at the point of injection. A certain residual has to be maintained in the boiler water.
Your ak group representative will recommend the optimum dosage necessary to ensure maximum program performance according to your specific system parameters.
FEEDING
ak 1100 can be fed neat or in any convenient dilution. Minimum solution strength for dilution is 10%. A stainless steel quill is recommended for injection.
ak 1100 should be fed to points that will allow maximum reaction time (e.g. deaerator storage tank).
ak 1100 must be fed continuously; any interruption in feed will result in corrosion formation and possible tube failure. If feedwater is used for steam attemperation, the product must be fed downstream of the attemperation water takeoff.
ak 1100 should be used with a scale inhibitor for complete boiler treatment program.
NOTE: To prevent catalyst precipitation, ak 1100 should not be mixed with alkaline treatments.
MATERIALS: Storage and application equipments (pumps, lines) should be made of Buna-N, EPDM, Hypalon, Neoprene, Plasite 6000, PE, PP, PU, PVC, Teflon, Stainless steel 304+316 (may discolor), Vinyl or Viton. Do not use Aluminum, Brass, Carbon steel, Copper, Nickel or Plasite 4005+7122 in contact with the neat product.
HANDLING-STORAGE-SHIPPING
As a standard precaution with all chemicals we recommend the use of personal protective equipments such as goggles and rubber gloves when handling. Consult the Material Safety Data Sheet as the only official source of Environmental and Safety information.
ak 1100 can be stored for at least 24 months from date of shipping if kept in its original, unopened container and under normal warehouse conditions. Protect from freezing and from exposure to high temperature.
ak 1100 is available in non-returnable containers of different sizes.
APPLICATION METHOD AND QUANTITY
The dosage quantity of the product changes according to the operating conditions and water chemistry of the system. ak group representative will propose the appropriate dosage quantity to ensure maximum conditioning performance based on the distributed system parameters.
MAKS 1200U SCALE INHIBITOR
GENERAL DESCRIPTION
ak 1200 U is an “all-organic” non-corrosive boiler feed water treatment.
PRINCIPAL USES
ak 1200 U is designed to prevent scale and corrosion formation in feedwater boiler systems.
PRODUCT BENEFITS
- Prevents scale formation and resulting tube failures
- Supports internal metal passivation in feedwater and boiler system
- Easy to use and apply
- Complies with FDA and USDA regulations in food industry, sterilization and steam humidification
DOSAGE
The specific dosage of ak 1200 U varies depending on the operating characteristics of your system and the water chemistry.
Your ak group representative will recommend the optimum dosage necessary to ensure maximum program performance according to your specific system parameters.
FEEDING
ak 1200 U is applied neat or diluted with demineralized water, condensate (<35oC) or deaerated boiler feedwater via a stainless steel quill into the suction side of feedwater pump.
ak 1200 U must be fed continuously; any interruption in feed will result in scale or deposit formation and possible tube failure. If feedwater is used for steam attemperation, the product must be fed downstream of the attemperation water takeoff.
MATERIALS: Storage and application equipments (pumps, lines) should be made of stainless steel, PE, PVC and PP. Do not use aluminum, copper, copper alloys, nickel or mild steel in contact with the neat product.
HANDLING-STORAGE-SHIPPING
As a standard precaution with all chemicals we recommend the use of personal protective equipments such as goggles and rubber gloves when handling. Consult the Material Safety Data Sheet as the only official source of Environmental and Safety information.
ak 1200 U can be stored for at least 24 months from date of shipping if kept in its original, unopened container and under normal warehouse conditions. Protect from freezing and from exposure to high temperature.
ak 1200 U is available in non-returnable containers of different sizes.
APPLICATION METHOD AND QUANTITY
The dosage quantity of the product changes according to the operating conditions and water chemistry of the system. ak group representative will propose the appropriate dosage quantity to ensure maximum conditioning performance based on the distributed system parameters.